This innovative Turner Hastings ceiling mounted sensor flushing kit intelligently detects arrival at the urinal and activates a 2 second pre-flush. Then a 2 minute timer will then start, when the timer times out the solenoid valve will open for a 10 second flush. These settings can be individually customised to suit the needs of the installation. This system connects directly to mains water supply so there is no need for an in-wall cistern. It can operate one or two urinals with its single solenoid valve (will flush two urinals simultaneously). It is available in mains power with an Australian power point, or in battery operated with a 9 volt battery. A visible LED indicates sensing, flushing, countdown to flush (delay) and battery condition.